If your furnace or air handler is running but no air is coming out of the vents, or if the blower runs intermittently and then stops, the motor’s internal thermal overload switch may have tripped. This small safety device shuts the motor down when it overheats, protecting it from damage. Resetting it can restore airflow and save you a service call, but you need to do it safely and correctly. Before starting, turn off power to the unit at the breaker or disconnect switch, and let the motor cool for at least half an hour if it feels hot.
What You’ll Need
- Screwdriver (flathead or Phillips, depending on your unit)
- Flashlight or work light
- Multimeter (optional, for testing continuity)
- Gloves (optional, for grip and protection)
Step-by-Step
- Turn off the power. Locate the circuit breaker for your furnace or air handler and switch it to the off position. If there is a disconnect switch near the unit, turn that off as well. Verify power is off by trying to run the thermostat—nothing should happen.
- Access the blower compartment. Remove the access panel that covers the blower. On most furnaces, this is a rectangular panel held by two or three screws or clips. Set the screws aside in a safe place.
- Locate the blower motor. The blower is a cylindrical or square metal housing with a wheel inside, usually mounted near the bottom of the furnace. The motor is attached to one end of this housing.
- Find the reset switch. Look on the motor’s side or end. It is a small, round or rectangular button, often red or black, sticking out from the motor casing. Some motors have a small rubber cap covering the button; others have a metal tab that you push in. It may be labeled “RESET” or have a small diagram.
- Press the reset button. Firmly push the button in until you feel a click. If it is a tab, push it in the direction indicated by the arrow. Hold it for a second, then release. You should hear or feel a distinct click.
- Check for other reset mechanisms. Some blower motors have a thermal overload that resets automatically when cool, but if there is no button, the motor may have a separate overload relay on the furnace control board. Look for a small red button on the circuit board near the motor wiring.
- Replace the access panel. Align the panel and reinstall the screws or clips. Make sure it is secure.
- Restore power. Turn the breaker back on. Wait a few seconds, then set the thermostat to call for heat or cool.
- Test the blower. Listen for the motor to start and feel for airflow at the vents. If it runs, the reset worked.
- Monitor for repeat trips. Watch the system for the next hour. If the blower stops again, the switch will likely trip again, indicating a deeper problem.
Common Mistakes
- Resetting while hot: Pressing the button when the motor is still hot will often cause it to trip again immediately. Always let it cool first.
- Forgetting to turn off power: Working on a live motor risks electric shock. Always disconnect power first.
- Pressing the wrong button: Some motors have a small drain plug or a vent that looks like a reset button. If it doesn’t click, you are not pressing the reset.
- Ignoring the cause: A tripped switch is a symptom, not the problem. If you reset it without addressing why it overheated, it will trip again.
- Overtightening the panel: Snug is fine; stripping screws makes future access harder.
Tips
- Clean the blower wheel and motor housing while you have the panel off. Dust buildup is a common cause of overheating.
- Check the air filter. A clogged filter restricts airflow, causing the motor to work harder and overheat. Replace it if dirty.
- Make sure the blower compartment door is fully sealed. Many furnaces rely on that door to complete an electrical safety circuit; if it is loose, the unit won’t run.
- If the motor has been running for years, consider that it may be nearing the end of its life. A motor that trips frequently may need replacement.
- Take a photo of the wiring before you touch anything, in case you need to reference it later.
Troubleshooting
If the reset button won’t press in: It may be stuck from corrosion or debris. Use a small flathead screwdriver to gently push it. If it still won’t move, the switch may be broken, and the motor needs professional attention.
If the motor still doesn’t start after resetting: First, check that power is actually reaching the motor. Use a multimeter to test for voltage at the motor’s wiring terminals. If there is no power, the problem could be the thermostat, limit switch, or control board. If there is power but the motor hums and doesn’t spin, the motor’s capacitor or bearings may be faulty.
If the motor starts but trips again within a few minutes: This indicates a real overheating issue. Check for a dirty blower wheel, a seized bearing (the motor may feel hot and hard to turn by hand), or a failing motor. You may need to replace the motor or call a technician.
If you cannot find any reset button: Some newer motors have no manual reset—they reset automatically once cool. If the motor is cool and still not running, the thermal overload may be internal and non-resettable, meaning the motor needs replacement.
If the breaker trips when you restore power: This points to a short circuit or a grounded motor winding. Do not keep resetting the breaker; call a professional.
Frequently Asked Questions
Q: How often should I reset the blower motor switch?
A: Ideally, never. A single reset might be a fluke, but if you need to reset it more than a couple of times a season, you have an underlying issue that needs fixing.
Q: Can I reset the blower motor without turning off the power?
A: No. Always turn off power to avoid electric shock. The reset button is small, and your hand or tool could easily slip into live wiring.
Q: What causes the blower motor to overheat?
A: The most common causes are a dirty air filter, a blocked vent, a dirty blower wheel, a failing capacitor, or worn motor bearings. Each makes the motor work harder.
Q: How long should I wait before resetting after the motor overheats?
A: Wait until the motor is cool to the touch, which usually takes at least half an hour. Resetting while hot will likely cause it to trip again.
Q: My blower motor has no reset button. What now?
A: Many modern motors reset automatically when they cool down. If yours doesn’t run after cooling, the thermal overload may be internal and non-serviceable, meaning the motor needs replacement.
Q: Is it safe to run the furnace with the blower motor reset button taped down?
A: Absolutely not. That bypasses the safety protection and can cause a fire or permanent motor damage. Never defeat a safety switch.